Potentiometric Auto Titrator (Titra+)

Labindia Analytical Potentiometric Titrator Titra+ comes with quick interchangeable imported burette assemblies with intelligent recognition for its volume size.This potentiometric autotitrator is perfect for all types of industrial applications. The Titra+ has composite differential electrode amplifier unit for potentiometric and voltametric/Karl Fisher titration having connectivity to various electrodes. Three standard modes of titration namely incremental, equilibrium and cut-off mode is provided to perform all types of titrations. There is a real time clock for time display and report printout with run time indication. With a balance interface to directly transfer the weight. 50 methods can be stored and report of method parameter can be printed in Titra+.

DOWNLOAD PDF

  • Standard Features of Automatic Titrator
    • Advanced Microcontroller-Based Design: User-friendly, state-of-the-art product design with alphanumeric splash waterproof polyester soft keys for the keyboard. User-interactive software in dialogue mode for ease of operation, with protection against invalid entries.
    • Vortex Stirrer: For vigorous and homogeneous stirring with a specially designed glass propeller for total chemical inertness.
    • Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette factor for dispensing corrections is available for true endpoint calculations.
    • Composite Differential Electrode Amplifier Unit: For potentiometric and voltametric/KF titrations, with connectivity to various electrodes. Temperature sensor with 4-line measurement technique ensures correct temperature indication.
    • Three Standardized Titration Modes: Incremental, equilibrium, and cut-off by pH mode to perform almost all types of titration. The instrument prints the appropriate electrode type based on the selected titration method.
    • Measured Variable Display: During titration, the measured variable (electrode potential or pH value) is displayed along with the dispensed volume and number of End Points (EP) detected.
    • User-Selectable End Point (EP) Evaluation: Up to 9 EP during the run, with calculation by first, last, largest, all, or selected EP, with results displayed and printed.
    • Alphanumeric Entries: Sample name, titrant name, identification number, date, and electrode type used for authentication. Includes factory-entered customer name and instrument serial number on report printouts, ensuring GLP compliance.
    • Dispenser Functionality: Can be used as a dispenser for fixed-volume dosing or dilution, allowing for manual titration with user-defined doses and mV indication.
    • Pre-Dispense Facility: Selectable dose and time for quick titrant addition without disturbing the titration trend.
    • Automatic Evaluation of Molarity: For titrant standardization, with storage of 20 molarities and retrieval for calculation.
    • Compliance: ASTM D664, D2896 & D4739 for TAN and TBN analysis for oil samples.
    • Titrant Temperature Factor: For volume correction.
    • Result Recalculation Facility: Printouts available in different units such as molarity, factor, % assay (wt), % volume (ml), ppm, mg/l, mg/g, ml/g, g/l, meq/l, mol/kg, TAN, & TBN for oil samples.
    • Reprocessing of Threshold and EP Calculation: Recalculation of EP without performing a new run.
    • Statistical Function: Run selectivity to calculate mean, standard deviation (S.D.), relative standard deviation (R.S.D.), and coefficient of variation (C.V.) for the last 10 repeat run results, which can be viewed or printed.
    • User-Programmed Selectivity for Report Format: Complying with GLP requirements:
      • Report with parameters and results.
      • Data table with mV, pH, mV, mV/ml, 2nd derivative, and volume (μl).
      • Graphical report showing mV vs. μl titration curve.
      • Graphical report of 1st derivative graph vs. μl titration curve.
      • Graphical report of 2nd derivative curve.
      • Report of method parameters for 50 methods.
      • Condensed report of titration parameters and results.
      • Auto evaluation report for multi-EP samples (EP1, EP2-EP1, etc.).
    • Report Access: Reports can be obtained even after resetting/power off/power failure.
    • Real-Time Clock (RTC): For time display and report printout with runtime indication.
    • Balance Interface: Direct transfer of sample weight.
    • Two-Tier Password Protection: Admin and user-level protection for method editing.
    • Conversion to Karl Fischer Titrations: TITRA can be converted for Karl Fischer titrations by changing the burette assembly. All specifications of LABINDIA Karl Fischer Titrator are applicable.

Potentiometric Auto Titrator (Titra+)

Labindia Analytical Potentiometric Titrator Titra+ comes with quick interchangeable imported burette assemblies with intelligent recognition for its volume size.This potentiometric autotitrator is perfect for all types of industrial applications. The Titra+ has composite differential electrode amplifier unit for potentiometric and voltametric/Karl Fisher titration having connectivity to various electrodes. Three standard modes of titration namely incremental, equilibrium and cut-off mode is provided to perform all types of titrations. There is a real time clock for time display and report printout with run time indication. With a balance interface to directly transfer the weight. 50 methods can be stored and report of method parameter can be printed in Titra+.

DOWNLOAD PDF

  • Standard Features of Automatic Titrator
    • Advanced Microcontroller-Based Design: User-friendly, state-of-the-art product design with alphanumeric splash waterproof polyester soft keys for the keyboard. User-interactive software in dialogue mode for ease of operation, with protection against invalid entries.
    • Vortex Stirrer: For vigorous and homogeneous stirring with a specially designed glass propeller for total chemical inertness.
    • Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette factor for dispensing corrections is available for true endpoint calculations.
    • Composite Differential Electrode Amplifier Unit: For potentiometric and voltametric/KF titrations, with connectivity to various electrodes. Temperature sensor with 4-line measurement technique ensures correct temperature indication.
    • Three Standardized Titration Modes: Incremental, equilibrium, and cut-off by pH mode to perform almost all types of titration. The instrument prints the appropriate electrode type based on the selected titration method.
    • Measured Variable Display: During titration, the measured variable (electrode potential or pH value) is displayed along with the dispensed volume and number of End Points (EP) detected.
    • User-Selectable End Point (EP) Evaluation: Up to 9 EP during the run, with calculation by first, last, largest, all, or selected EP, with results displayed and printed.
    • Alphanumeric Entries: Sample name, titrant name, identification number, date, and electrode type used for authentication. Includes factory-entered customer name and instrument serial number on report printouts, ensuring GLP compliance.
    • Dispenser Functionality: Can be used as a dispenser for fixed-volume dosing or dilution, allowing for manual titration with user-defined doses and mV indication.
    • Pre-Dispense Facility: Selectable dose and time for quick titrant addition without disturbing the titration trend.
    • Automatic Evaluation of Molarity: For titrant standardization, with storage of 20 molarities and retrieval for calculation.
    • Compliance: ASTM D664, D2896 & D4739 for TAN and TBN analysis for oil samples.
    • Titrant Temperature Factor: For volume correction.
    • Result Recalculation Facility: Printouts available in different units such as molarity, factor, % assay (wt), % volume (ml), ppm, mg/l, mg/g, ml/g, g/l, meq/l, mol/kg, TAN, & TBN for oil samples.
    • Reprocessing of Threshold and EP Calculation: Recalculation of EP without performing a new run.
    • Statistical Function: Run selectivity to calculate mean, standard deviation (S.D.), relative standard deviation (R.S.D.), and coefficient of variation (C.V.) for the last 10 repeat run results, which can be viewed or printed.
    • User-Programmed Selectivity for Report Format: Complying with GLP requirements:
      • Report with parameters and results.
      • Data table with mV, pH, mV, mV/ml, 2nd derivative, and volume (μl).
      • Graphical report showing mV vs. μl titration curve.
      • Graphical report of 1st derivative graph vs. μl titration curve.
      • Graphical report of 2nd derivative curve.
      • Report of method parameters for 50 methods.
      • Condensed report of titration parameters and results.
      • Auto evaluation report for multi-EP samples (EP1, EP2-EP1, etc.).
    • Report Access: Reports can be obtained even after resetting/power off/power failure.
    • Real-Time Clock (RTC): For time display and report printout with runtime indication.
    • Balance Interface: Direct transfer of sample weight.
    • Two-Tier Password Protection: Admin and user-level protection for method editing.
    • Conversion to Karl Fischer Titrations: TITRA can be converted for Karl Fischer titrations by changing the burette assembly. All specifications of LABINDIA Karl Fischer Titrator are applicable.

Description

AeroTrak™+ Portable Airborne Particle Counters (APCs) are ideal for all industries for cleanroom certification, monitoring and specialized tasks including gas testing and filter scanning. Engineered for you, they provide the newest features you’ve been asking for in a portable particle counter: Data integrity (including Annex 1) Communication options Intuitive GUI — requires no manuals to operate, significantly reducing the chance for user error and simplifying monitoring for environmental contamination These features lead to a better user experience and easy compliance. Built in standards for configuration and reports to meet the standards driving the market include: ISO 14644-1:2015 – Cleanrooms and associated controlled environments ISO 21501-4:2018 – Calibration standards EU GMP Annex 1 (2008 and 2022) – Good Manufacturing Practice: Manufacture of Sterile Medical Products China GMP Standalone or as part of an easy to use complete monitoring system, AeroTrak™+ Portable Particle Counter A100 Series meets your needs. Click here to view a series of Videos & Quick Tips.

Reviews

There are no reviews yet.

Be the first to review “Potentiometric Auto Titrator (Titra+)”

Your email address will not be published. Required fields are marked *

Let's Get In Touch

Your laboratory instruments should serve you, not the other way around. We're happy to help you.