Automatic Karl Fischer Titrator (KAFI+ SMART)

The Karl Fischer titrator KAFI Smart is the advanced version of the KAFI+. With a 7” touch screen and user friendly icons it’s a ideal instrument for every lab. Quick interchangeable imported burette assemblies with intelligent recognition for its different volume size gives flexibility to users. With 21 CFR part 11 compliant software customers can have multiple users with password protection and various privileges options. In KAFI Smart user authentication is performed for each and every operation done. PDF reports can be generated as well.

DOWNLOAD PDF

  • Standard Features of Karl Fischer Kafi+ Smart
    • Advanced Microcontroller-Based Design: User-friendly, state-of-the-art product design with interactive software for ease of operation, ensuring protection against invalid entries.
    • Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette validation factor for dispensing correction is available for true endpoint volume.
    • Peripheral Connectivity Recognition: The system recognizes proper connectivity of peripherals like burette, stirrer, electrode, pen drive, etc., and provides an indication in case of improper connectivity.
    • Large Memory Capacity: For method storage with suitable scientific parameters that comply with GLP (Good Laboratory Practices).
    • Sample Identification and Authentication: Sample name & identification number with date and time for authentication. Daily auto-incremented run number and factory-entered customer name & instrument serial number on report printouts ensure the system is foolproof and GLP compliant.
    • Moisture Leak Monitoring: Quick monitoring and automatic neutralization of moisture leakage into the vessel to keep it ready for the next titration.
    • End Point Delay: Up to 100 seconds for slow moisture-releasing samples.
    • Leak Rate Correction: On-line leak rate correction available.
    • Magnetic Stirrer: Microcontroller-based variable speed magnetic stirrer with digital indication.
    • Calculation Modes:
      • Weight/Weight
      • Volume/Volume
      • Volume/Density
    • Selectable Report Format (GLP Compliant):
      • A) Report with titration parameters and results.
      • B) Report of method parameters.
      • C) Condensed report of titration parameters and results.
      • D) Graph printout of reaction trend.
    • Report Accessibility: Reports can be obtained even after resetting, power off, or power failure conditions.
    • Statistic Function: Run selectivity to find the mean, standard deviation (S.D.), relative standard deviation (R.S.D.), and coefficient of variation (C.V.) of the last 10 repeat run results, which can be viewed or printed.
    • ASTM Standard Compliance: Compliant for the analysis of oil samples.
    • Date & Time Display: For report printouts with run time indication.
    • Balance Interface: Direct transfer of sample weight.

    21 CFR PART 11 COMPLIANCE

    • Audit Trail: For all activities with search facility, report generation, and printing.
    • 200 User IDs: Alphanumeric entries for user name, password, and role-based privilege selection.
    • User Authentication: Performed for each and every operation done by the user.
    • PDF Report File Creation: Customizable PDF report files can be created via print.
    • USB Printing: Eliminates the need for a serial port to connect with the instrument. The user can take printouts on a printer via Wi-Fi connectivity.
    • Electronic Signature Functionality: Included for enhanced security.
    • Manual Archive and Data Backup Facility: Available for data preservation.
    • Multi-Level Roles with Password Protection: Ensures system security.
    • User Authentication: Ensures that every operation is authenticated by the user.

Automatic Karl Fischer Titrator (KAFI+ SMART)

The Karl Fischer titrator KAFI Smart is the advanced version of the KAFI+. With a 7” touch screen and user friendly icons it’s a ideal instrument for every lab. Quick interchangeable imported burette assemblies with intelligent recognition for its different volume size gives flexibility to users. With 21 CFR part 11 compliant software customers can have multiple users with password protection and various privileges options. In KAFI Smart user authentication is performed for each and every operation done. PDF reports can be generated as well.

DOWNLOAD PDF

  • Standard Features of Karl Fischer Kafi+ Smart
    • Advanced Microcontroller-Based Design: User-friendly, state-of-the-art product design with interactive software for ease of operation, ensuring protection against invalid entries.
    • Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette validation factor for dispensing correction is available for true endpoint volume.
    • Peripheral Connectivity Recognition: The system recognizes proper connectivity of peripherals like burette, stirrer, electrode, pen drive, etc., and provides an indication in case of improper connectivity.
    • Large Memory Capacity: For method storage with suitable scientific parameters that comply with GLP (Good Laboratory Practices).
    • Sample Identification and Authentication: Sample name & identification number with date and time for authentication. Daily auto-incremented run number and factory-entered customer name & instrument serial number on report printouts ensure the system is foolproof and GLP compliant.
    • Moisture Leak Monitoring: Quick monitoring and automatic neutralization of moisture leakage into the vessel to keep it ready for the next titration.
    • End Point Delay: Up to 100 seconds for slow moisture-releasing samples.
    • Leak Rate Correction: On-line leak rate correction available.
    • Magnetic Stirrer: Microcontroller-based variable speed magnetic stirrer with digital indication.
    • Calculation Modes:
      • Weight/Weight
      • Volume/Volume
      • Volume/Density
    • Selectable Report Format (GLP Compliant):
      • A) Report with titration parameters and results.
      • B) Report of method parameters.
      • C) Condensed report of titration parameters and results.
      • D) Graph printout of reaction trend.
    • Report Accessibility: Reports can be obtained even after resetting, power off, or power failure conditions.
    • Statistic Function: Run selectivity to find the mean, standard deviation (S.D.), relative standard deviation (R.S.D.), and coefficient of variation (C.V.) of the last 10 repeat run results, which can be viewed or printed.
    • ASTM Standard Compliance: Compliant for the analysis of oil samples.
    • Date & Time Display: For report printouts with run time indication.
    • Balance Interface: Direct transfer of sample weight.

    21 CFR PART 11 COMPLIANCE

    • Audit Trail: For all activities with search facility, report generation, and printing.
    • 200 User IDs: Alphanumeric entries for user name, password, and role-based privilege selection.
    • User Authentication: Performed for each and every operation done by the user.
    • PDF Report File Creation: Customizable PDF report files can be created via print.
    • USB Printing: Eliminates the need for a serial port to connect with the instrument. The user can take printouts on a printer via Wi-Fi connectivity.
    • Electronic Signature Functionality: Included for enhanced security.
    • Manual Archive and Data Backup Facility: Available for data preservation.
    • Multi-Level Roles with Password Protection: Ensures system security.
    • User Authentication: Ensures that every operation is authenticated by the user.

Description

AeroTrak™+ Portable Airborne Particle Counters (APCs) are ideal for all industries for cleanroom certification, monitoring and specialized tasks including gas testing and filter scanning. Engineered for you, they provide the newest features you’ve been asking for in a portable particle counter: Data integrity (including Annex 1) Communication options Intuitive GUI — requires no manuals to operate, significantly reducing the chance for user error and simplifying monitoring for environmental contamination These features lead to a better user experience and easy compliance. Built in standards for configuration and reports to meet the standards driving the market include: ISO 14644-1:2015 – Cleanrooms and associated controlled environments ISO 21501-4:2018 – Calibration standards EU GMP Annex 1 (2008 and 2022) – Good Manufacturing Practice: Manufacture of Sterile Medical Products China GMP Standalone or as part of an easy to use complete monitoring system, AeroTrak™+ Portable Particle Counter A100 Series meets your needs. Click here to view a series of Videos & Quick Tips.

Reviews

There are no reviews yet.

Be the first to review “Automatic Karl Fischer Titrator (KAFI+ SMART)”

Your email address will not be published. Required fields are marked *

Let's Get In Touch

Your laboratory instruments should serve you, not the other way around. We're happy to help you.